Swageless eye terminals.
Swageless fitting method (see attached picture).
May be hand fitted without use of special tools.
Please , follow the below instructions:
1) Simply slip the body of terminal over the full diameter of the cable.
2) Unlay the outer wires and fit the cone over the centre core.
3) Re-lay the outer wires .
4-5) Ease the ends of the wires into the head of the fitting.
6-7) Draw the body up to the head and screw together apply a light quantity of anti-seize lubricant on the male thread.
Code | Rope (mm) | L1 (mm) | L2 (mm) | L3 (mm) | K1 (mm) | Breaking load (Kg) |
---|---|---|---|---|---|---|
115.03 | 2.5-3 | 6 | 14 | 5.2 | 48 | 710 |
115.04 | 4 | 6.5 | 16 | 6.2 | 55 | 1375 |
115.05 | 5 | 8 | 18 | 7.2 | 64 | 2100 |
115.06 | 6 | 11 | 23 | 9.2 | 85 | 3040 |
115.07 | 7 | 13 | 23 | 10 | 87 | 4150 |
115.08 | 8 | 14 | 25 | 10.8 | 90 | 7810 |
115.10 | 10 | 16 | 25 | 10.8 | 110 | 9500 |
115.12 | 12 | 19 | 36 | 18.8 | 140 | 10800 |
115.14 | 14 | 22 | 38 | 21.5 | 165 | 16500 |
115.16 | 16 | 25 | 50 | 24.5 | 165 | 20000 |